HYDROGEN | ICSC: 0001 |
(cylinder) H2 Molecular mass: 2.0 RTECS # MW8900000 ICSC # 0001 UN # 1049 EC # 001-001-00-9 |
TYPES OF HAZARD/ EXPOSURE |
ACUTE HAZARDS/ SYMPTOMS |
PREVENTION |
FIRST AID/ FIRE FIGHTING |
FIRE |
Extremely flammable.
Many reactions may cause fire or explosion.
|
NO open flames, NO sparks, and NO smoking.
|
Shut off supply; if not possible and no risk to surroundings, let the fire burn itself out; (see notes)
water spray,
powder,
carbon dioxide.
|
EXPLOSION |
Gas/air mixtures are explosive.
|
Closed system, ventilation, explosion-proof electrical equipment and lighting.
Use non-sparking handtools.
Do not handle cylinders with oily hands.
|
In case of fire: keep cylinder cool by spraying with water.
Combat fire from a sheltered position.
|
EXPOSURE |
|
|
|
|
Dizziness.
Asphyxia.
Laboured breathing.
Unconsciousness.
|
Closed system and ventilation.
|
Fresh air, rest.
Refer for medical attention.
|
|
ON CONTACT WITH LIQUID: FROSTBITE.
|
Cold-insulating gloves.
Protective clothing.
|
ON FROSTBITE: rinse with plenty of water, do NOT remove clothes.
Refer for medical attention.
|
|
|
Safety goggles,
or face shield.
|
|
|
|
|
|
SPILLAGE DISPOSAL | STORAGE | PACKAGING & LABELLING | ||
Evacuate danger area!
Consult an expert!
Ventilation.
Remove vapour with fine water spray.
|
Fireproof.
Cool.
|
F+ symbol R: 12 S: 9-16-33 UN Hazard Class: 2.1 |
||
SEE IMPORTANT INFORMATION ON BACK | ||||
|
|
HYDROGEN | ICSC: 0001 |
I M P O R T A N T D A T A |
| |||
PHYSICAL PROPERTIES |
| |||
ENVIRONMENTAL DATA |
|
|||
NOTES | ||||
Addition of small amounts of a flammable substance or an increase in the oxygen content of the air strongly enhances combustibility.
High concentrations in the air cause a deficiency of oxygen with the risk of unconsciousness or death.
Check oxygen content before entering area.
No odour warning if toxic concentrations are present.
Measure hydrogen concentrations with suitable gas detector (a normal flammable gas detector is not suited for the purpose).
After use for welding, turn valve off; regularly check tubing, etc., and test for leaks with soap and water.
The measures mentioned in section PREVENTION are applicable to production, filling of cylinders, and storage of the gas.
|
ADDITIONAL INFORMATION | |||||
|
|
||||
|
|